Features of Drive Medical Medneb Compressor Nebulizer Disposable Neb Kit MQ5600
- Compact, desktop unit
- Piston driven system
- Delivers medications to the bronchial passages in an aerosol form
- Perfect for medicating patients who resist medicines or cannot take them due to any reasons
- The compressor is used in conjunction with a jet (pneumatic) nebulizer to convert certain inhalable drugs into an aerosol form for inhalation by a patient
How does the Drive MEDNEB Compressor Nebulizer work?
- The majority of medications designed for compressor nebulizer use are in liquid form.
- The nebulizer’s “cup” is filled with this liquid medication.
- Flexible tubing connects the compressor to the nebulizer, and the compressor produces a particular air pressure and flow that, in a sense, “drives” the nebulizer.
- The compressor’s compressed air starts the nebulizer’s capacity to transform the liquid medication into an extremely thin mist.
- The aerosol cloud-like mist is then expelled from the nebulizer and inhaled into the lungs, where the body quickly absorbs it.
What to buy with MEDNEB Nebulizer?
- Drive Aerosol Mask
- AIRFREE IRIS 3000 Filterless Air Purifier
- Bluechip Hospital Patient Allergy Proof Pillow
Also Available Separately:
- Drive Disposable Nebulizer Kit
How to use Drive Compressor Nebulizer?
- Before each use inspect the Compressor and nebulizer cup assembly for damage or wear, and replace as needed.
- Place the Compressor on a table or flat, stable surface. Be sure you can easily reach the controls when seated. Do not use this device on the floor.
- With the power switch in the O (OFF) position, plug the power cord into an appropriate electrical wall outlet.
- Connect one end of the tubing to the compressor air-outlet connector.
- Assemble the nebulizer cup and add the indicated medication to the nebulizer’s cup before use.
- Attach the other end of the tubing to the air-inlet connector found at the bottom of the nebulizer cup.
- Turn on the Compressor by pressing the power switch to the I (ON) position and begin treatment.
- If treatment needs to be interrupted, simply press the power switch to the O (OFF) position.
- When the treatment is complete, turn off the compressor by pressing the power switch to the O (OFF) position and unplug the unit from the electrical outlet.
- Always unplug this device immediately after use.
- Do not use this product in or near explosive environments, or where aerosol (spray) products are being used.
- Do not pump combustible liquids or vapors with the product or use in or near an area where flammable or explosive liquids or vapors may exist.
- Do not operate this product in an oxygen-enriched environment, i.e. oxygen tent or oxygen hood.
- Use only in well-ventilated areas.
How to clean MEDNEB Compressor Nebulizer?
- All parts of the nebulizer, except the tubing, should be cleaned.
- With the power switch in the “ Off” position, unplug the power cord from the wall outlet.
- Disconnect the tubing from the air-inlet connector and set it aside.
- Disassemble the mouthpiece or mask from the cap. Open the nebulizer by turning the cap counterclockwise and remove the baffle.
- Wash all items, except tubing, in a hot water/dishwashing detergent solution. Rinse under hot tap water for 30 seconds to remove detergent residue. Allow to air dry.
- For reusable nebulizers only, it can be cleaned daily in a dishwasher using the top shelf or by following the above cleaning procedure.
Disinfect Daily
- Using a clean container or bowl, soak items in three parts hot water to one part white vinegar for 30 minutes OR use a medical bacterial-germicidal disinfectant available through your provider. Be sure to follow the manufacturer’s instructions carefully.
- With clean hands, remove items from the disinfectant solution, rinse under hot tap water, and air dry on a clean paper towel. Store in a zip-lock bag.
- Keep the outer surface of the tubing dust-free by wiping regularly. Nebulizer tubing does not have to be washed because only filtered air passes through it.
Note:
- The Drive Disposable Nebulizer will last at least 15 days and possibly longer, depending on usage. Proper cleaning will also help extend the life of the nebulizer.
- Because it is disposable, we recommend that an extra nebulizer be kept on hand at all times.
- The Drive Reusable Nebulizer is dishwasher safe and may be cleaned and reused for up to one year.
Compressor Cleaning:
- With the power switch in the “Off ” position, unplug the power cord from the wall outlet.
- Wipe outside the compressor cabinet with a clean damp cloth every few days to keep dust-free.
Filter Change:
- Filter should be changed every 6 months or sooner if the filter discolors.
- Remove the filter by grasping it firmly and pulling it out of the unit. Discard the old filter.
- Replace with a new Drive filter. Additional filters should be purchased from your Drive provider.
- Push the new filter into position
Note: Do not reuse or wash the filter or substitute any other material such as cotton for a Drive air-inlet filter. It will result in compressor damage.
Medneb Compressor Nebulizer Machine Guides